New Jersey Infrared Commercial & Residential Roof Inspections

 On-Roof Thermography of Moisture

 

The highly sensitive FLIR T-400 infrared camera quickly identifies thermal patterns indicative of moisture problem areas in your roof.  Infrared thermography is non-destructive so it is particularly well suited to find thermal anomalies created by trapped moisture under roofing membrane.

 

The Basic Concept

During the day the radiant heat of the sun heats the combined roof structure.  After sunset the roof begins to shed this accumulated heat back to the atmosphere.  The added thermal mass of moist insulation holds this heat longer.  During this time there is a window of opportunity when a skilled thermographer will be able to image these warmer areas.  The results can be quite dramatic.  Therefore, tests are performs at night, using thermal imaging equipment to locate the hot thermal patterns, as called anomalies throughout your roof.

 

These tests are non-invasivecost efficient ways to extend the life of your roof.  The areas of concern are marked on the roof and in the detailed, comprehensive PDF report.  Most roofs can be extended to last an additional 12-20 years when an infrared survey program is implemented in conjuction with a roofing repair company.


Roof Maintenance in General

Waterproofing problems manifest themselves in two ways, leakage and entrained moisture contamination. Leakage is pretty simple, although the leak inside the building rarely directly relates to the exact spot on the roof, since the water flows down the slope of the roof to a spot that is not sealed and into the building at that point. Most leaks occur where the waterproofing is sealed or where there is a penetration of the roof. Since most types of roof systems absorb some amount of water, it is harder to find the exact spot of water contamination in the insulation because it may not leak into the building until it has absorbed all the water it can hold.

 

There are three types of surveys that are used to find water in a roof:

  • Nuclear gauges - which count neutrons
  • Capacitance meters - which measure resistance
  • Infrared - which measures heat.

Both nuclear gauges and capacitance meters are used to take spot readings on a 5’ X 5’, 10' X 10' or 20' X 20' grid on the roof. These measurements are used to extrapolate where the water is from the readings obtained from the gauges. These surveys are very labor-intensive and therefore expensive. They are good for types of roofs that do not gain or lose much solar energy and therefore do not lend themselves to infrared.

Roof Infrared Basics

During the day, the sun radiates energy onto the roof and into the roof substrate, and then at night, the roof radiates the heat back into outer space. This is called radiational cooling. Areas of the roof that are of a higher mass (wet) retain this heat longer than that of the lower mass (dry) areas. Infrared imagers can detect this heat and "see" the warmer, higher mass areas, during the "window" of uneven heat dissipation.


  Understanding Infrared Roof Imagery

Infrared imagery is often a grayscale picture whose scales (or shades of gray) represent the differences in temperature and emissivity of objects in the image. As a general rule, objects in the image that are lighter in color are warmer and darker objects are cooler. No object in the images is detected via visible light wavelengths (400-700 nanometers) rather, only from infrared wavelengths in the 3000-5000 nanometers or in the 3-5 micrometers (microns) range. Lights and other relatively hot objects are very evident, but as a result of their heat, and not light emissions.
 

When an image is taken by our infrared camera, it is often recorded on videotape and/or digitally saved to a hard drive and later converted to a digital image file with the help of a computer. The image may then be modified in a number of ways to enhance its value to the end user. The highest resolution infrared images are usually found on the digital media, while the printed pictures may be used as a convenient reference when making the building drawings or accompanying a roof report.

Areas of roof moisture contamination often manifest themselves as warmer (lighter colored) areas that may be nebulous in shape and sometimes mottled in appearance, although they are commonly found in linear or puddle-like shapes. The linear shapes many times follow low areas, drainage routes, roof edges and seams. Puddle-like round or oblong shapes often form around roof penetrations such as mechanical equipment, standpipes, vents and drains. The wet areas are lighter in color because the latent heat (from daylight sunshine) in the trapped water mass is greater than in the dry, functioning insulation or roof substrate. After sunset when the roof structure cools down, wet areas of roof insulation and other materials continue to radiate heat, allowing our sensitive infrared cameras to detect the sources of heat and record them for later analysis.                

 

 

                                        
            

On-Roof Infrared                                           Aerial Roof Infrared                         

We create detailed, high-quality and easy to                                            We create detailed, high-quality and easy to           
understand reports documenting roof moisture.                                       understand reports documenting roof moisture.

Roof professionals can then use the information                                        Roof professionals can then use the information

to verify the wet areas and write specifications                                      to verify the wet areas and write specifications

to repair the roof.                                                                                        to repair the roof.

                                   

Why Aerial Infrared


Performing infrared roof moisture surveys while standing on the roof is not the best method because imagery from a walk-on survey is not as useful as aerial imagery. The same laws of physics apply to both aerial IR and on-roof IR. A dry roof, low winds and no rain are needed on the night of the survey. However, the "window" when the roof is radiating heat differently from wet and dry areas is longer with aerial infrared because slight nuances of temperatures over large areas are recognizable. A high angle of view and high resolution are needed to produce usable imagery. We use large-format infrared cameras, which have at least 512 x 512 staring array detectors (262,144 pixels). From an altitude of 1,200 – 1,500 feet above the roof with over a quarter of a million pixels, the ground resolution element is about six inches square.

Visual photographs are taken earlier in the day or the next day. Both visual and infrared images are used to do the analysis by overlaying the AutoCAD drawing of the roof ‘over’ the digitized photographs and thermographs. The drawings are created indicating areas of suspected moisture contamination. The result is a report where visual, infrared and AutoCAD components (printed and video) are well matched and lined-up.

Fixed-wing aerial infrared imaging provides many advantages over on-roof infrared imaging:

  • Access to multiple levels of the roof is not a problem.
  • High-angle, straight down infrared images lessen reflection problems. 
    High-resolution images capture large areas at once, making report writing easier and less expensive to produce.
  • Plan view allows for infrared images, visual images and AutoCAD drawings to be reconciled closely. As a result, the report is clear, concise and easy to understand (see Figure 4,5,6).
  • Plan view imaging allows accurate marking of areas of suspect roof moisture contamination.
  • The printed AutoCAD drawings can be used on the roof to paint areas of moisture contamination directly on the roof (after verification), if desired.
  • The trending of roof moisture becomes possible.

Aerial IR allows the building owner to buy only the report he needs at that time. Further processing can be done on roof areas of specific concern. The report components are as follows in order by cost:

  • Unedited videotape. The raw videotape of the infrared flight over the building.
  • Edited videotape. An edited videotape can be made from the original digital video.
  • Printed thermographs. Printed infrared thermographs of each roof section can be captured and printed in high-resolution.
  • Aerial photographs. Printed digital and/or conventional photographs of the roof (straight down) and site (beauty shots of the building and property) can be printed. Note: A straight down photograph of a roof section aids significantly in the infrared analysis, showing stains, equipment and roof boundaries, etc.
  • AutoCAD drawings. Accurate AutoCAD drawings can be made, then printed and saved to disk
  • Digital and printed report. A complete quantitative aerial infrared roof moisture survey report would include all of the above, printed in high resolution and saved to a CD.

The biggest advantage of aerial infrared is on roofs that are the most difficult to image from any distance or angle. Roofs that, for instance, have a lot of ballast, are covered with reflective coatings or for whatever reason are impossible to image from the roof. With high-resolution, plan view aerial imagery, slight nuances of temperature can be seen from far enough away to actually see the pattern of heat and make a determination of where the problems are.

Imagery Examples

The aerial infrared is a provided service of Roof Scan IR, United Infrared (AITscan) has performed qualitative infrared thermographic surveys of roof moisture on thousands of buildings. We brought together all the components that truly make us the state-of-the-art in the field of infrared thermography. Our deliverable product is the best on the market today. We use high-resolution infrared imagers, digital recording equipment, techniques that have been refined over the years and the attitude that we are going to obtain the best imagery possible and produce a professional report in a timely manner.

Visible Photograph does not show any signs of leaks


 

 Thermograph clearly shows thermal patterns of trapped moisture under the membrane (light gray areas)

  CAD Drawing provides road map to help you and your roofer coordinate efforts.


Why cover a wet roof?

ROOF ASSET MANAGEMENT

Example of mosaic visible image of a low-sloped roof

Example of mosaic thermal image of a low-sloped roof

Example of mosaic visible image of a low-sloped roof with CAD drawing overlay

Example of mosaic thermal image of a low-sloped roof with CAD drawing overlay

If you are not familiar with this widely used and accepted technology, please call me to

discuss your questions, comments or concerns.



Peter W. Bennett, Owner
www.AFullHouseInspection.com
Residential & Commercial Building Inspections
Infrared Thermal Imaging Services
(Energy Loss, Plumbing, Moisture & Roof Leaks, Electrical Systems, Structural Defects)
530 Prospect Avenue Little Silver, NJ 07739 
Office 732-758-9887 Cell 732-245-9817
NJ Home Inspector Lic#GI371 
NJ DEP Radon MET11140
Certified Infrared Thermographer No.7406
Certified Energy Inspector No. 1364   
Certified ASHI Member #205748 